Mission® Expert
Urine Reagent Strips & Analyzers
Products are Available for International Distribution Only – Not Available in the US
Mission® Expert
Expert Urine Reagent Strips
The Mission® Expert Urinalysis Strips are a great tool to get insight into the patient’s overall health and their metabolic, liver and kidney functions. It is a very cost effective screening tool. The Mission® Expert Urinalysis Strips are very reliable and have comparable performance to the market leaders.
Features
Easy to Use
- Compatible with visual and/or analyzer reading
- 11 strip combinations for visual reading
- 7 strip combinations for analyzer reading
- 24 Months shelf life for closed canisters
- 90 days shelf life once the canister was opened
Reliable Results
- Increased Ascorbic Acid resistance
- Reduces false-negative results for Glucose, Blood, Nitrite, and Bilirubin
- Performance equivalent to the market leader
- High quality color chart improves visual reading accuracy
- Results in 2 minutes
What do the Parameters Mean?
Ascorbic Acid: People taking vitamin C may have large amounts of ascorbic acid in their urine. Ascorbic acid is known to interfere with the accuracy of some chemical test strips, causing them to be falsely low or falsely negative. Examples of tests that may be affected include the urine dipstick tests for glucose, blood, bilirubin, nitrite, and glucose.
Blood: Blood in the urine is called hematuria. A number of things can cause hematuria including UTI, Kidney infection, medication, menstruation, strenuous exercise.
- Expected result: Negative
Bilirubin: The detection of Bilirubin in the urine is an early indication of liver disease. Bilirubin is the breakdown product of hemoglobin. Note: These two parameters (Urobilinogen and Bilirubin) are commonly used to screen for possible liver disease.
- Expected Result: negative
Urobilinogen: the presence of excreted urobilinogen suggests a possible deterioration of liver functions. Urobilinogen is the breakdown product of bilirubin.
- Expected result: less than 17 µmol/l (< 1mg/dl)
Ketone: The control of urinary ketone is useful in managing and monitoring type 1 diabetes.
- Expected Results: Negative
Glucose: Glucose in the urine could indicate diabetes or renal glycosuria.
- Expected Results: Negative
Note: These two parameters are commonly used to screen for possible metabolic disorders
Protein: This test is usually run to screen for kidney disease. Protein in the urine is called Proteinuria.
- Expected result: Negative
Nitrite: Screening for possible asymptomatic infections caused by nitrate-reducing bacteria – Suggesting a possible UTI. Note: These two parameters (Leukocytes and Nitrite) are commonly used to screen for possible Urinary Tract Infection (UTI).
- Expected result : Negative
Leukocytes: The detection of white blood cells in the urine suggests a possible UTI.
- Expected result : Negative
pH: Measures the acidity in your urine which may be a sign of kidney stones. Your pH varies during the day going from more acid in the am to more alkaline in the pm.
- Expected result : Low
Specific Gravity: Evaluates the body’s water balance (hydration) and urine concentration and helps evaluate kidney functions and possible kidney diseases.
- Expected Results: low at 1,000 but normal ranges from 1.020 to 1.030
Product Specifications
▲Type of Strip:
- Visual Strip Size: 1-6 Parameters: 5 x 80 mm; 7-11 Parameters: 112 x 5 mm
- U120/U500 Strip Size: 1-11 Parameters: 5 x 112 mm
- “E” means extended strip length for 1-6 Parameters
- Also available in canisters of 25, 50 and 150 strips.
√ CE Marked for sale in the European Community
Expert U120 Urine Analyzer
The Mission® Expert U120 Urine Analyzer is to be used with the Mission® Expert Urine Reagent Strips. The U120 makes urine testing easier and provides accurate results in 60 seconds.
Features
Fast and Accurate
- Up to 120 tests/hour in Continuous Test Option
- Test categories include Routine, STAT and QC
- Automatic calibration for accurate results and easy operation
Efficient
- Can read strips with up to 11 parameters, including Ascorbic Acid
- Capture Patient ID via Manual Entry or Barcode Reader
- Capable to transfer data to an external computer or LIS
Reliable
- Automatically stores the last 2,000 results
- Print up to 3 copies per test
- Option to print results on sticker paper
Product Specifications
Features | Specifications |
Type | Manual |
Methodology | Reflectance Photometry |
Detection | Photosensitive Diode |
Throughput |
|
Test Categories | Routine, STAT and QC |
Memory | Last 2,000 results |
Strip Incubation Time | 1 Minute |
Wavelength of Monochromatic LED | 525 nm and 635 nm |
Default strip types U033 | 11U, 10S, 9N, 5KE, 4UE, 2GE |
Default strip types U034 | 11UW, 10SW, 9NW, 5KEW, 4UEW, 2GEW, 2CEW |
Strips Available | 2 – 11 parameters |
Strip Size | 108 x 5 mm |
Combinations per Analyzer |
|
Analyzer Ports |
|
Data Entry Capabilities | Operator/Patient ID – Manual Entry and Barcode Reader (Up to 20 characters) |
Connection Capabilities |
|
Major Readable Barcodes |
|
Calibration | Automatic |
Available Languages on the Screen | English and additional language(s) |
Operating Conditions | 0-40°C (32-104° F); < 85% RH |
Storage Conditions | -5-50°C (23-122° F); < 90% RH |
Power Source | 100-240 VAC, 50-60 Hz |
Dimensions | 27.2 x 26.9 x14.6 cm (10.7″ x 10.6″ x 5.7″ ) |
Display Dimensions | 10.8 x 5.7 cm (4.2″ x 2.2″) |
Weight | 2.6 kg (5.7 lbs) without batteries or power supply |
Expert U500 Urine Analyzer
The Mission® Expert U500 Urine Analyzer is a great tool to use with the Mission® Expert Urinalysis Reagent Strips. This analyzer has the capability of running up to 500 tests per hour and saving up to 2,000 results. The Mission® Expert U500 Urine Analyzer makes high volume testing easy while providing you with confidence in the accuracy of the results.
Features
Fast and Accurate
- Up to 500 tests/hour in Continuous Test Option
- Test categories include Routine, STAT and QC
- Automatic calibration for accurate results and easy operation
Efficient
- Can read strips with up to 11 parameters, including Ascorbic Acid
- Capture Patient ID via Manual Entry or Barcode Reader
- Capable to transfer data to an external computer or LIS
Handy Features
- Automatically stores the last 2,000 results
- Print up to 3 copies per test
- Option to print results on sticker paper
Product Specifications
Features | Specifications |
Analyzer Type | Semi- Automatic |
Methodology | Reflectance Photometry |
Detection | Photosensitive Diode |
Throughput | 500 tests/ hour (Measuring cycle: 7 seconds/ test) |
Test Categories | Routine STAT and QC |
Lockout Functions |
|
Memory | Last 2,000 results |
Strip Incubation Time | 1 Minute |
Wavelength | 525 and 635 nm |
Default strip types U033 | 11U, 10S, 9N, 5KE, 4UE, 2GE |
Default strip types U034 | 11UW, 10SW, 9NW, 5KEW, 4UEW, 2GEW, 2CEW |
Strips Available | 2 – 11 parameters |
Strip Size | 108 x 5 mm |
Parameter Order | Can select the order of parameters for display and print out |
Combinations per analyzer |
|
Waste Disposal Capacity | Up to 150 strips |
Analyzer Ports* |
|
Data Entry Capabilities* |
|
Data Transfer Options* | Data for single entry, all the data in database, data from specific date |
Data Search Options* | Test number, positive results, patient ID, date, STAT results, QC results |
Software Updates* | Can be updated via RS232C cable |
Connection Capabilities* |
|
Major Readable Barcodes |
|
Screen Type* | TFT LCD color touch screen (11.5 x 9 cm) |
LIS Interface* | Formatted and compatible with ACON standard interface, HL-7 compliant and other interfaces |
Calibration | Automatic |
Available Languages on the Screen* | More than 8 languages available, including English |
Operating Conditions | 0-40″C (32-104″F); < 85% RH |
Storage Conditions | -5-50 °C (23-122°F); < 90% RH |
Power Source | 100-240 VAC, 50-60 Hz |
Dimensions | 36.6 x 28.3 x 19.5 cm (14.4″ x 11.1″ x 7.7″) |
Display Dimensions | 11.5 x 9 cm (4.5″ x 3.5″) |
Weight | 4.0 kg (8.8 lbs.) without batteries or power supply |