Mission® Urinalysis

Reliable solutions for all your urinalysis testing needs

Mission URS

Products are Available for Worldwide Distribution

Mission® Urinalysis

Mission® Urinalysis is a family of products designed uniquely to meet the needs of healthcare professionals at the point of care.   Our product offering includes a variety of urine analyzers and urine reagent test strips with a wide range of parameters and combinations to meet your testing needs.

Urine Reagent Strips

Mission Urine Reagent Strips

The Mission® Urinalysis Strips are a great tool to get insight into the patient’s overall health and their metabolic, liver and kidney functions. It is a very cost effective screening tool. The Mission® Urinalysis Strips are very reliable and have comparable performance to the market leaders.

Features

Reliable Results

  • Analytical sensitivity comparable to market leaders
  • High quality color chart ensures accurate visual reading

Ease of Use

  • Compatible for visual and analyzer reading
  • Over 35 different combinations available
  • 24 months shelf life for unopened canisters
  • 3 months shelf life once the canister is opened

Packaging Options

Canister Packaging

  • Available in 100 strips per canister
  • MA/CRE strips available in 25 strips per canister

Pouch Packaging

  • Individually packaged strips available in kits of 3 or 6 strips for visual reading only (includes 1 color chart)
What do the Parameters Mean?
Mission Urine Reagent Strips Parameters

Mission Urine Reagent Strips Parameters

Leukocytes: The detection of white blood cells in the urine suggests a possible UTI.

  • Expected result : Negative

Nitrite: Screening for possible asymptomatic infections caused by nitrate-reducing bacteria – Suggesting a possible UTI. Note: These two parameters (Leukocytes and Nitrite) are commonly used to screen for possible Urinary Tract Infection (UTI).

  • Expected result : Negative

Urobilinogen: the presence of excreted urobilinogen suggests a possible deterioration of liver functions. Urobilinogen is the breakdown product of bilirubin.

  • Expected result: less than 17 µmol/l (< 1mg/dl)

Protein: This test is usually run to screen for kidney disease. Protein in the urine is called Proteinuria.

  • Expected result: Negative

pH: Measures the acidity in your urine which may be a sign of kidney stones. Your pH varies during the day going from more acid in the am to more alkaline in the pm.

  • Expected result : Low

Blood: Blood in the urine is called hematuria. A number of things can cause hematuria including UTI, Kidney infection, medication, menstruation, strenuous exercise.

  • Expected result: Negative

Specific Gravity: Evaluates the body’s water balance (hydration) and urine concentration and helps evaluate kidney functions and possible kidney diseases.

  • Expected Results: low at 1,000 but normal ranges from 1.020 to 1.030

Ketone: The control of urinary ketone is useful in managing and monitoring type 1 diabetes.

  • Expected Results: Negative

Bilirubin: The detection of Bilirubin in the urine is an early indication of liver disease. Bilirubin is the breakdown product of hemoglobin. Note: These two parameters (Urobilinogen and Bilirubin) are commonly used to screen for possible liver disease.

  • Expected Result: Negative

Glucose: Glucose in the urine could indicate diabetes or renal glycosuria.

  • Expected Results: Negative

Note: These two parameters are commonly used to screen for possible metabolic disorders.

Ascorbic Acid: People taking vitamin C may have large amounts of ascorbic acid in their urine. Ascorbic acid is known to interfere with the accuracy of some chemical test strips, causing them to be falsely low or falsely negative. Examples of tests that may be affected include the urine dipstick tests for glucose, blood, bilirubin, nitrite, and glucose.

Urine Controls

Mission Urine Controls

The Mission® Urine Controls are used with the Mission® Urinalysis Reagent Strips, and Urine Analyzers for optimum quality control.

Features

Reliable Results

  • Ensures accurate results for all parameters
  • Validate urinalysis results in any setting

Quick and Easy Testing

  • Use with Mission® and Mission® Expert Urinalysis Reagent Strips and Urine Analyzers for optimum quality control
  • Used for quality control of Urine Analyzers
  • Quick and easy protocol allows for fast results with minimal error

Convenient Packaging

Two packaging options available

Dropper Tip

  • Dropper tip bottles provide efficient use of the control solution
  • Easily drop the control solution onto each reagent pad using the dropper tip bottle

Diptube

  • Diptube packaging allows for quick testing similar to using a urine specimen
  • Simply dip the strip into the control solution and read the result
Product Specifications

FeaturesSpecifications
Product NameLiquid Urine ControlLiquid Diptube Urine Control
Test ParametersLEU, NIT, URO, PRO, pH, BLO, SG, KET, BIL, GLU, ASC, ALB, CRE, CA (13)
Solution Detection Levels, Level 1Negative: LEU, NIT, URO, PRO, pH, BLO, SG, KET, BIL, GLU, ASC, ALB, CRE, CA
Solution Detection Levels, Level 2Positive: LEU, NIT, URO, PRO, pH, BLO, SG, KET, BIL, GLU, ALB CRE, CA; and Negative ASC
Compatible Urine Strips
  • Mission® Urinalysis Reagent Strips,
  • Mission®  Expert Urinalysis Reagent Strips
Reading Time/StabilityRefer to insertRefer to insert
Storage Temperature 2-8° C 2-8° C
Memory24 Months24 Months
Opened Control Stability30 days at 15-30°C or until the expiration date at 2-8°C30 days at 15-30°C or until the expiration date at 2-8°C
Maximum Tests per Unit20 or 40 tests/bottle20 tests/diptube

U120 Smart Urine Analyzer

Mission U120 Urine Analyzer

The Mission® U120 Urine Analyzer is a great tool to use with the Mission® Urinalysis Reagent Strips.  The analyzer has the capability of running up to 120 tests per hour and to save and recall 2,000 results.  The Mission® U120 Urine Analyzer simplifies testing and while providing accurate results. The analyzer is 510(k) Cleared and CLIA Waived for use with the Mission® Urinalysis Reagent Strips and Mission® Urine Controls.

Features

Fast and Accurate

  • Up to 120 tests/hour in Continuous Test Option
  • Test categories include Routine, STAT and QC
  • Automatic calibration for accurate results and easy operation

Convenient Features

  • Can read strips with up to 11 parameters, including Microalbumin/Creatine/Ascorbic Acid
  • Record Operator/Patient ID by Manual Entry and Barcode Reader
  • Capable of data transfer to an external computer or LIS

Reliable

  • Automatically stores last 2,000 results
  • Can print up to 3 copies per test for convenient reviewing and easy record keeping
  • Option to print results on sticker paper for quick and simple record management
Product Specifications

FeaturesSpecifications
TypeSemi-Automatic
MethodologyReflectance Photometry
DetectionPhotosensitive Diode
Throughput
  • Single Test Option: 60 tests/hour
  • Continuous Test Option: 120 tests/hour
Test CategoriesRoutine, STAT and QC
MemoryLast 2,000 results
Strip Incubation Time1 Minute
Wavelength of Monochromatic LED525 nm and 635 nm
Strips Available1-11 parameters (108 x 5 mm); see URS Parameters
Total Combinations Per Analyzer15 Combinations
Analyzer Ports
  • RS232C Port for Barcode Reader or Data Transfer
  • USB Port for Data Transfer
  • 25 Pin Parallel Port for External Printer
Data Entry CapabilitiesOperator/Patient ID – Manual Entry and Barcode Reader (Up to 20 characters)
Connection Capabilities
  • USB or RS232C Data Transfer Cable (optional)
  • RS232C Barcode Reader (optional)
  • Optional External Printer (not included)
Major Readable Barcodes
  • Code 128
  • Code 39
  • Codabar (NW-7)
  • EAN 8
  • EAN 13
  • Interleave 25
  • UPCA
  • UPCE
CalibrationAutomatic
LanguagesEnglish, French, German, Italian, Portuguese and Spanish
Operating Conditions0-40°C (32-104° F); < 85% RH
Storage Conditions -5-50°C (23-122° F); < 90% RH
Power Source100-240 VAC, 50-60 Hz
Dimensions27.2 x 26.9 x 14.6 cm (10.7″ x 10.6″ x 5.7″)
Display Dimensions10.8 x 5.7 cm (4.2″ x 2.2″)
Weight2.6 kg (5.7 lbs) without batteries or power supply

 

U500 Urine Analyzer

Mission U500 Urine Analyzer

The Mission® U500 Urine Analyzer is a great tool to use with the Mission® Urinalysis Reagent Strips.  The analyzer has the capability of running up to 500 tests per hour and saving and recalling 2,000 results.  The Mission® U500 Urine Analyzer simplifies testing and while providing accurate results. This analyzer is 510(k) Cleared.

Features

Fast and Accurate

  • Up to 500 tests/hour
  • Test categories include Routine, STAT and QC
  • Automatic calibration for accurate results and easy operation

Efficient

  • Can read strips with up to 11 parameters, including Microalbumin/Creatine/Ascorbic Acid
  • Software includes 12 strip types
  • Ability to build a work list
  • Capability of data transfer to an external computer or LIS

Reliable

  • Automatically stores last 2,000 results
  • Can print up to 3 copies per test for convenient reviewing and easy record keeping
  • Option to print results on sticker paper for quick and simple record management
Product Specifications
FeaturesSpecifications
Analyzer TypeSemi-Automatic
MethodologyReflectance Photometry
DetectionPhotosensitive Diode
Throughput500 tests/hour (Measuring cycle: 7 seconds/test)
Test CategoriesRoutine, STAT and QC
Lockout Functions
  • Strip Lockout: Available Upon Request
  • User/QC Lockout: Included with option to turn ON/OFF
MemoryLast 2,000 Records
Strip Incubation Time1 Minute
Wavelength525 and 635 nm
Parameter OrderCan select the order of parameters for display and print out
Strip Combinations per Analyzer12 combinations available
LanguagesEnglish, French, German, Indonesian, Italian, Polish, Portuguese and Spanish
Waste Disposal CapacityUp to 150 Strips
Analyzer Ports
  • RS232C Port for Barcode Reader or Data Transfer
  • 25 Pin Parallel Port for External Printer
Data Entry CapabilitiesOperator/Patient ID – Manual Entry and Barcode Reader (Up to 25 characters)
Connection Capabilities
  • RS232C Data Transfer Cable (optional)
  • RS232C Barcode Reader (optional)
  • Optional External Printer (not included)
Major Readable Barcodes
  • Code 128
  • Code 39
  • Codabar (NW-7)
  • EAN 8
  • EAN 13
  • Interleaved 25
  • UPCA
  • UPCE
CalibrationAutomatic
Operating Conditions0-40°C (32-104°F); -<85% RH
Storage Conditions-5-50°C (23-122°F); -<90% RH
Power Source100-240 VAC, 50-60 Hz
Dimensions36.6 x 28.3 x 19.5cm (14.4″ x 11.1″ x 7.7″)
Display Dimensions11.5 x 9.0 cm (4.5″ x 3.5″)
Weight4.0 kg (8.8 lbs) without batteries or power supply 

 

Analyzers Accessories

Urinalysis Barcode Reader

Barcode Reader

Optional Bar-code Reader connects to the analyzer for faster input of information. It scans the canister code for quick canister code recognition to operate the analyzer as well as quick entry of Patient ID. Both canister code and Patient ID can be entered manually as well.

Mission Printer Paper Rolls

Printer Paper Rolls

Printer paper rolls is available in both Thermal paper and Sticker paper. Printing results may either be automatic or manual. Can print up to 3 copies per test results for convenient record management.

Mission Data Transfer Kit

Data Transfer Kit

Data Transfer Kit is used for data transfer to Personal Computer (PC) or Laboratory Information System (LIS). RS232 cable is required for connection to a personal computer and the analyzer in order to download data to PC or LIS.

Resource Library

Browse our Resources Library for documents available for download.

Skip to content