Mission® Urinalysis
Reliable solutions for all your urinalysis testing needs
Products are Available for Worldwide Distribution
Mission® Urinalysis
Mission® Urinalysis is a family of products designed uniquely to meet the needs of healthcare professionals at the point of care. Our product offering includes a variety of urine analyzers and urine reagent test strips with a wide range of parameters and combinations to meet your testing needs.
Urine Reagent Strips
The Mission® Urinalysis Strips are a great tool to get insight into the patient’s overall health and their metabolic, liver and kidney functions. It is a very cost effective screening tool. The Mission® Urinalysis Strips are very reliable and have comparable performance to the market leaders.
Features
Reliable Results
- Analytical sensitivity comparable to market leaders
- High quality color chart ensures accurate visual reading
Ease of Use
- Compatible for visual and analyzer reading
- Over 35 different combinations available
- 24 months shelf life for unopened canisters
- 3 months shelf life once the canister is opened
Packaging Options
Canister Packaging
- Available in 100 strips per canister
- MA/CRE strips available in 25 strips per canister
Pouch Packaging
- Individually packaged strips available in kits of 3 or 6 strips for visual reading only (includes 1 color chart)
What do the Parameters Mean?
Leukocytes: The detection of white blood cells in the urine suggests a possible UTI.
- Expected result : Negative
Nitrite: Screening for possible asymptomatic infections caused by nitrate-reducing bacteria – Suggesting a possible UTI. Note: These two parameters (Leukocytes and Nitrite) are commonly used to screen for possible Urinary Tract Infection (UTI).
- Expected result : Negative
Urobilinogen: the presence of excreted urobilinogen suggests a possible deterioration of liver functions. Urobilinogen is the breakdown product of bilirubin.
- Expected result: less than 17 µmol/l (< 1mg/dl)
Protein: This test is usually run to screen for kidney disease. Protein in the urine is called Proteinuria.
- Expected result: Negative
pH: Measures the acidity in your urine which may be a sign of kidney stones. Your pH varies during the day going from more acid in the am to more alkaline in the pm.
- Expected result : Low
Blood: Blood in the urine is called hematuria. A number of things can cause hematuria including UTI, Kidney infection, medication, menstruation, strenuous exercise.
- Expected result: Negative
Specific Gravity: Evaluates the body’s water balance (hydration) and urine concentration and helps evaluate kidney functions and possible kidney diseases.
- Expected Results: low at 1,000 but normal ranges from 1.020 to 1.030
Ketone: The control of urinary ketone is useful in managing and monitoring type 1 diabetes.
- Expected Results: Negative
Bilirubin: The detection of Bilirubin in the urine is an early indication of liver disease. Bilirubin is the breakdown product of hemoglobin. Note: These two parameters (Urobilinogen and Bilirubin) are commonly used to screen for possible liver disease.
- Expected Result: Negative
Glucose: Glucose in the urine could indicate diabetes or renal glycosuria.
- Expected Results: Negative
Note: These two parameters are commonly used to screen for possible metabolic disorders.
Ascorbic Acid: People taking vitamin C may have large amounts of ascorbic acid in their urine. Ascorbic acid is known to interfere with the accuracy of some chemical test strips, causing them to be falsely low or falsely negative. Examples of tests that may be affected include the urine dipstick tests for glucose, blood, bilirubin, nitrite, and glucose.
Urine Controls
The Mission® Urine Controls are used with the Mission® Urinalysis Reagent Strips, and Urine Analyzers for optimum quality control.
Features
Reliable Results
- Ensures accurate results for all parameters
- Validate urinalysis results in any setting
Quick and Easy Testing
- Use with Mission® and Mission® Expert Urinalysis Reagent Strips and Urine Analyzers for optimum quality control
- Used for quality control of Urine Analyzers
- Quick and easy protocol allows for fast results with minimal error
Convenient Packaging
Two packaging options available
Dropper Tip
- Dropper tip bottles provide efficient use of the control solution
- Easily drop the control solution onto each reagent pad using the dropper tip bottle
Diptube
- Diptube packaging allows for quick testing similar to using a urine specimen
- Simply dip the strip into the control solution and read the result
Product Specifications
Features | Specifications | |
Product Name | Liquid Urine Control | Liquid Diptube Urine Control |
Test Parameters | LEU, NIT, URO, PRO, pH, BLO, SG, KET, BIL, GLU, ASC, ALB, CRE, CA (13) | |
Solution Detection Levels, Level 1 | Negative: LEU, NIT, URO, PRO, pH, BLO, SG, KET, BIL, GLU, ASC, ALB, CRE, CA | |
Solution Detection Levels, Level 2 | Positive: LEU, NIT, URO, PRO, pH, BLO, SG, KET, BIL, GLU, ALB CRE, CA; and Negative ASC | |
Compatible Urine Strips |
| |
Reading Time/Stability | Refer to insert | Refer to insert |
Storage Temperature | 2-8° C | 2-8° C |
Memory | 24 Months | 24 Months |
Opened Control Stability | 30 days at 15-30°C or until the expiration date at 2-8°C | 30 days at 15-30°C or until the expiration date at 2-8°C |
Maximum Tests per Unit | 20 or 40 tests/bottle | 20 tests/diptube |
U120 Smart Urine Analyzer
The Mission® U120 Urine Analyzer is a great tool to use with the Mission® Urinalysis Reagent Strips. The analyzer has the capability of running up to 120 tests per hour and to save and recall 2,000 results. The Mission® U120 Urine Analyzer simplifies testing and while providing accurate results. The analyzer is 510(k) Cleared and CLIA Waived for use with the Mission® Urinalysis Reagent Strips and Mission® Urine Controls.
Features
Fast and Accurate
- Up to 120 tests/hour in Continuous Test Option
- Test categories include Routine, STAT and QC
- Automatic calibration for accurate results and easy operation
Convenient Features
- Can read strips with up to 11 parameters, including Microalbumin/Creatine/Ascorbic Acid
- Record Operator/Patient ID by Manual Entry and Barcode Reader
- Capable of data transfer to an external computer or LIS
Reliable
- Automatically stores last 2,000 results
- Can print up to 3 copies per test for convenient reviewing and easy record keeping
- Option to print results on sticker paper for quick and simple record management
Product Specifications
Features | Specifications |
Type | Semi-Automatic |
Methodology | Reflectance Photometry |
Detection | Photosensitive Diode |
Throughput |
|
Test Categories | Routine, STAT and QC |
Memory | Last 2,000 results |
Strip Incubation Time | 1 Minute |
Wavelength of Monochromatic LED | 525 nm and 635 nm |
Strips Available | 1-11 parameters (108 x 5 mm); see URS Parameters |
Total Combinations Per Analyzer | 15 Combinations |
Analyzer Ports |
|
Data Entry Capabilities | Operator/Patient ID – Manual Entry and Barcode Reader (Up to 20 characters) |
Connection Capabilities |
|
Major Readable Barcodes |
|
Calibration | Automatic |
Languages | English, French, German, Italian, Portuguese and Spanish |
Operating Conditions | 0-40°C (32-104° F); < 85% RH |
Storage Conditions | -5-50°C (23-122° F); < 90% RH |
Power Source | 100-240 VAC, 50-60 Hz |
Dimensions | 27.2 x 26.9 x 14.6 cm (10.7″ x 10.6″ x 5.7″) |
Display Dimensions | 10.8 x 5.7 cm (4.2″ x 2.2″) |
Weight | 2.6 kg (5.7 lbs) without batteries or power supply |
U500 Urine Analyzer
The Mission® U500 Urine Analyzer is a great tool to use with the Mission® Urinalysis Reagent Strips. The analyzer has the capability of running up to 500 tests per hour and saving and recalling 2,000 results. The Mission® U500 Urine Analyzer simplifies testing and while providing accurate results. This analyzer is 510(k) Cleared.
Features
Fast and Accurate
- Up to 500 tests/hour
- Test categories include Routine, STAT and QC
- Automatic calibration for accurate results and easy operation
Efficient
- Can read strips with up to 11 parameters, including Microalbumin/Creatine/Ascorbic Acid
- Software includes 12 strip types
- Ability to build a work list
- Capability of data transfer to an external computer or LIS
Reliable
- Automatically stores last 2,000 results
- Can print up to 3 copies per test for convenient reviewing and easy record keeping
- Option to print results on sticker paper for quick and simple record management
Product Specifications
Features | Specifications |
Analyzer Type | Semi-Automatic |
Methodology | Reflectance Photometry |
Detection | Photosensitive Diode |
Throughput | 500 tests/hour (Measuring cycle: 7 seconds/test) |
Test Categories | Routine, STAT and QC |
Lockout Functions |
|
Memory | Last 2,000 Records |
Strip Incubation Time | 1 Minute |
Wavelength | 525 and 635 nm |
Parameter Order | Can select the order of parameters for display and print out |
Strip Combinations per Analyzer | 12 combinations available |
Languages | English, French, German, Indonesian, Italian, Polish, Portuguese and Spanish |
Waste Disposal Capacity | Up to 150 Strips |
Analyzer Ports |
|
Data Entry Capabilities | Operator/Patient ID – Manual Entry and Barcode Reader (Up to 25 characters) |
Connection Capabilities |
|
Major Readable Barcodes |
|
Calibration | Automatic |
Operating Conditions | 0-40°C (32-104°F); -<85% RH |
Storage Conditions | -5-50°C (23-122°F); -<90% RH |
Power Source | 100-240 VAC, 50-60 Hz |
Dimensions | 36.6 x 28.3 x 19.5cm (14.4″ x 11.1″ x 7.7″) |
Display Dimensions | 11.5 x 9.0 cm (4.5″ x 3.5″) |
Weight | 4.0 kg (8.8 lbs) without batteries or power supply |
Analyzers Accessories
Barcode Reader
Optional Bar-code Reader connects to the analyzer for faster input of information. It scans the canister code for quick canister code recognition to operate the analyzer as well as quick entry of Patient ID. Both canister code and Patient ID can be entered manually as well.
Printer Paper Rolls
Printer paper rolls is available in both Thermal paper and Sticker paper. Printing results may either be automatic or manual. Can print up to 3 copies per test results for convenient record management.
Data Transfer Kit
Data Transfer Kit is used for data transfer to Personal Computer (PC) or Laboratory Information System (LIS). RS232 cable is required for connection to a personal computer and the analyzer in order to download data to PC or LIS.
Resource Library
Browse our Resources Library for documents available for download.